1
|
INPUT :
|
230V AC +/- 10%, single Phase
|
|
2.
|
OUTPUT :
|
+/-15V DC, 3A
|
|
3.
|
LINE REGULATION :
|
Less than 0.1% for change in input voltage from 207V to 253 V
|
|
4.
|
LOAD REGULATION :
|
+/-0.1% for change from no load to full load and vice versa
|
|
5
|
RIPPLE :
|
Less than 5mV RMS
|
|
6
|
DRAFT IN 24 Hrs. :
|
Less than 25%
|
|
7
|
OUTPUT VOLTAGE ADJUST:
|
+/- 5% of rated output.
|
|
8
|
PROTECTIONS :
|
Output will be protected against over loads, over voltages and continuous short circuits.
|
|
9
|
INDICATIONS ;
|
One LED each to indicate the availability of DC outputs.
|
|
10
|
TERMINATIONAS :
|
Input is given through a Circular connector and output is given through a PIRI Terminal.
|
|
11
|
OPERATING TEMP :
|
0 to 55 Degree
|
|
12
|
MECHANICAL SIZE :
|
3U Height X Half 19âââ¬ï¿½ Rack width x less than 300mm depth.
|
|
|
|
Two units fitted in full 19âââ¬ï¿½ Rack.
|
|
13
|
RELATIVE HUMIDITY :
|
0 to 90% without condensation.
|
|
14
|
TEMP. COEFFICIENT :
|
Less than 0.025% per Degree C.
|
|
15
|
POWER SUPPLY FAILURE ALARM :
|
Will be provided with relay contacts
|
|
16
|
PARALLEL OPERATION :
|
Will be provided
|